6 Core OPLC Cable Hybrid Fiber Optic Cable, Composite Low Voltage Outdoor Cable G652D

 

Suluhisho la kebo la mseto wa mseto lilitengenezwa ili kupunguza utata na gharama za usakinishaji kwenye tovuti za simu za mkononi, huruhusu waendeshaji simu wanaotumia usanifu wa RRH ili kusawazisha mchakato wa usakinishaji wa RRH na kuondoa hitaji na gharama ya kuweka kebo.Kebo mseto huchanganya nyuzi macho (multimode au modi moja) na kondakta wa shaba kwa ajili ya nishati ya DC katika kebo ya bati ya alumini yenye uzani mwepesi.


  • Mahali pa asili:Guangdong, Uchina
  • Jina la bidhaa:Kijeshi/Tactical Fiber Optic Cable
  • Idadi ya nyuzinyuzi:2-12 Hiari ya Msingi
  • Silaha:Kevlar+amored
  • Maelezo ya Bidhaa

    Lebo za Bidhaa

    Sehemu ya Msalaba wa Cable:

    OPLC

    Kipengele:

    1. Mtawanyiko wa chini na kupungua.
    2. Ukanda wa Alumini wa LAP hutumiwa karibu na msingi wa cable, ambao umejaa kiwanja cha kujaza ili kuilinda kutokana na kuingia kwa maji.
    3. Muundo sahihi, udhibiti sahihi wa urefu wa ziada wa nyuzi na mchakato tofauti wa kukwama hutoa sifa bora za mitambo na mazingira.
    4. Uwekaji silaha wa waya wa chuma na mkanda wa bati hufanya kebo kuwa na sifa nzuri za kustahimili unyevu na upinzani wa kuponda.
    5. Muundo wa kompakt na wepesi, utendakazi unaonyumbulika na unaostahimili bend.

    Viwango:

    Zingatia Standard YD/T 901 pamoja na IEC 60794-1.

    Maombi: 

    1 Inatumika kwa sanduku la usambazaji wa nje kwa bomba la jengo;juu;kuzikwa.
    2 Kutumika katika chumba vifaa vya mawasiliano ya macho, usambazaji mwanga frame uhusiano mwanga na macho
    Vyombo 3, vifaa vya kuunganisha kwenye mwanga.
    4 Inatumika kwa nyuzi za mkia na kuruka kwenye mstari.
    5 Inatumika kwa majengo yanayozunguka kwenye kebo.

    Vigezo vya Mbinu:

    Idadi ya nyuzi Muundo Kondaktaeneo la msalaba Kipenyo Uzito Nguvu ya mkazo Upinzani wa KupondaMuda Mrefu/MfupiN/100 mm Radi ya KukunjaTuli
    /Inayobadilikamm
    2 Uni-tube 1.0 9.4 92 300/600 300/1000 10D/20D
    4 Uni-tube 1.0 9.4 92 300/600 300/1000 10D/20D
    6 Uni-tube 1.0 9.4 92 300/600 300/1000 10D/20D
    8 Uni-tube 1.0 9.4 92 300/600 300/1000 10D/20D
    10 Uni-tube 1.0 9.4 92 300/600 300/1000 10D/20D
    12 Uni-tube 1.0 9.4 92 300/600 300/1000 10D/20D
    14 Uni-tube 1.0 9.4 92 300/600 300/1000 10D/20D
    16 Uni-tube 1.0 9.4 92 300/600 300/1000 10D/20D
    18 Uni-tube 1.0 9.4 92 300/600 300/1000 10D/20D
    20 Uni-tube 1.0 10.4 106 300/600 300/1000 10D/20D
    22 Uni-tube 1.0 10.4 106 300/600 300/1000 10D/20D
    24 Uni-tube 1.0 10.4 106 300/600 300/1000 10D/20D
    Idadi ya nyuzi Muundo Kondaktaeneo la msalaba Kipenyo Uzito Nguvu ya mkazo Upinzani wa KupondaMuda Mrefu/MfupiN/100 mm Radi ya KukunjaTuli
    /Inayobadilikamm
    2 Uni-tube 1.5 10.8 119 300/600 300/1000 10D/20D
    4 Uni-tube 1.5 10.8 119 300/600 300/1000 10D/20D
    6 Uni-tube 1.5 10.8 119 300/600 300/1000 10D/20D
    8 Uni-tube 1.5 10.8 119 300/600 300/1000 10D/20D
    10 Uni-tube 1.5 10.8 119 300/600 300/1000 10D/20D
    12 Uni-tube 1.5 10.8 119 300/600 300/1000 10D/20D
    14 Uni-tube 1.5 10.8 119 300/600 300/1000 10D/20D
    16 Uni-tube 1.5 10.8 119 300/600 300/1000 10D/20D
    18 Uni-tube 1.5 10.8 119 300/600 300/1000 10D/20D
    20 Uni-tube 1.5 11.3 127 300/600 300/1000 10D/20D
    22 Uni-tube 1.5 11.3 127 300/600 300/1000 10D/20D
    24 Uni-tube 1.5 11.3 127 300/600 300/1000 10D/20D

    Halijoto:

    Uendeshaji /Uhifadhi:-40°c +70°c

    Mchoro wa sehemu ya kebo

    Tabia za macho:

    Aina ya nyuzi 62.5um(OM1)850 nm 50um(OM2)850 nm/1300 nm G.652D1310 nm/1550 nm G.6551550 nm/1625 nm
    Attenuation upeo 3.5/1.5 3.5/1.5 0.36/0.22 0.22/0.26
    Attenuation kawaida 3.5/1.5 3.0/1.0 0.35/0.21 0.21/0.24

  • Iliyotangulia:
  • Inayofuata:

  • Acha Ujumbe Wako

    Andika ujumbe wako hapa na ututumie